Menu

Theme

Learn and fix · How-to · CHECKED ON 5.0.0

Timing diagrams and signal logging in Logisim-evolution

For a Logisim timing diagram, choose Simulate, then Timing diagram. The window lists your signals; choose Clocked mode and a clock, then step the clock with Ctrl+T or run it with Ctrl+K and the waveform fills in. Use File, Export Image in that window to save it as PNG, GIF, JPEG, SVG, TikZ or WaveDrom. Classic Logisim 2.7.1 has no timing diagram, only a Logging window that shows a table and can write a file.
FOR
Students writing lab reports and people debugging sequential circuits · Logisim-evolution 5.0.0, classic 2.7.1
CHECKED
11 Nov 2026
FIX TIME
about 10 min
Checked against Logisim-evolution 5.0.0 on 1 machines
On this page

Record your first timing diagram

We used a clock driving an 8-bit counter, the circuit from the clock guide.

  1. Open the timing diagram

    In the main window choose Simulate, then Timing diagram. The menu item is in the 5.0.0 Simulate menu (F46).

    Check: A second window opens with the tabs Options and Timing diagram.

  2. Choose the signals

    On the Options tab click Add or Remove under Signals and Formats. The dialog is titled “Drag signals to select or rearrange”. In our circuit all four signals were already in the viewed list.

    Check: The Signals to be viewed list holds the pins you want.

  3. Pick Clocked mode and the clock

    Logging Mode offers three modes; Clocked mode was selected. Clock Source showed CLK, and Clock Discipline was “capture on both edges”.

    Check: Clock Source shows your clock and Clock Discipline is set.

  4. Tick the clock

    Click the main window, then press Ctrl+T for one half cycle, or Ctrl+K to run the clock. See Clock, ticks and simulation controls.

    Check: The Timing diagram tab shows waveforms.

LAB lab-lnx · Linux lab5.0.02026-11-11

The Options tab of the timing diagram window. Boxes: Signals and Formats with an Add or Remove button, Logging Mode with Stop-motion mode, Continuous real-time mode and Clocked mode selected, Timing Options for Clocked mode with a time scale of 5.0 microseconds, a clock source CLK and a clock discipline of capture on both edges, and History with a Store unlimited history check box.

Timing diagram window, Options tab, Linux lab (F97).lab-lnx-le500-timing-options-01
Options tab of the timing diagram: signals, logging modes, clocked-mode time scale and history settings.
LAB lab-lnx · Linux lab5.0.02026-11-11

The dialog Drag signals to select or rearrange. Left list, Signals available in circuit: CLK, Counter, halt, Q. Right list, Signals to be viewed: CLK, Counter, Q and halt, each followed by a format in brackets. An OK button is at the bottom.

The signal chooser, Linux lab (F97).lab-lnx-le500-timing-signals-dialog-01
Dialog Drag signals to select or rearrange, with available signals on the left and chosen ones on the right.

After eight presses of Ctrl+T, which is four clock cycles, the counter read 0000 0100 (F97).

LAB lab-lnx · Linux lab5.0.02026-11-11

The Timing diagram tab after four clock cycles. Rows: CLK with alternating 0 and 1, the counter as a bus, Q as a bus and halt at 0. The Signal Value column reads 0000 0100 for the counter and for Q. A toolbar above has an Add or Remove Signals button.

Timing diagram of a counter after four clock cycles, Linux lab (F97).lab-lnx-le500-timing-recorded-01
Timing diagram tab after four clock cycles: rows for CLK, the counter, Q and halt.

The three logging modes

The Options tab lists three modes (F97). The descriptions below are in our words, from the window’s own help text.

Timing diagram logging modes
Stop-motion modeAfter the circuit settles, or at every change if you tick Capture fine-grained details.Combinational circuits and step-by-step runs.
Continuous real-time modeWhile the simulator runs, scaling each real second to a chosen amount of circuit time.Watching a free-running circuit.
Clocked modeAt each clock edge, rising, falling or both, or during the high or low half, depending on Clock Discipline.Counters and registers for lab reports.

The fine-grained option adds the short pulses that appear while signals settle, drawn as if each gate delayed by the Gate delay value. The window says the setting was 200 ns, greyed out until the option is ticked. We did not build a glitch circuit, so we have no screenshot of one. The History box offers unlimited history or a number of recent values to store; we did not test either.

Reading the diagram

The left column lists each signal and its current value. Single-bit signals are drawn as high and low; buses are drawn as a band with the value written inside. The time scale in our run was 5.0 µs per tick, and a clock cycle was 2 ticks, so 10.0 µs. Our export of the same run, drawn here from the data Logisim wrote, with one column per half cycle:

Clock and counter over four cycles, from our WaveDrom export (F97)
Show values as a table
half cycleCLKCounter
0000
1101
2001
3102
4002
5103
6003
7104
8004

We did not test the bus Expand and Format controls, zoom, or the cursor.

Export for a report

In the timing window choose File, then Export Image. The type list showed PNG, GIF, JPEG, TikZpicture (.tex), SVG and WaveDrom (.json). All six wrote a file for our counter; the PNG was 488 by 140 pixels (F97).

LAB lab-lnx · Linux lab5.0.02026-11-11

The export file chooser of the timing diagram. Fields Look In, File Name and Files of Type set to PNG Files. Buttons Export and Cancel.

Export Image from the timing window, Linux lab (F97).lab-lnx-le500-timing-export-dialog-01
File chooser for exporting the timing diagram, with the file type set to PNG Files.
LAB lab-lnx · Linux lab5.0.02026-11-11

The PNG written by the timing diagram export: four lanes for CLK, the counter, Q and halt, with the clock alternating and the counter bus changing at each rising edge.

The exported PNG itself, 488 by 140 pixels (F97).lab-lnx-le500-timing-exported-png-01
The exported timing diagram PNG: four lanes for CLK, the counter, Q and halt.

The WaveDrom file is plain JSON that a WaveDrom viewer can draw. Ours, for the counter run: timing-counter-wavedrom.json. The release notes say export bugs were fixed in 5.0.0; we did not compare versions.

Log values to a file

We found no option in the 5.0.0 timing window to log to a file, and the Simulate menu has no Logging item. To keep the numbers, export WaveDrom and read the data lists in it. Classic Logisim 2.7.1 does have a file log, below. To turn recorded values into a test vector, see Test vectors when that guide is available.

Where did the “Start Chronogram” button go?

Old tutorials mention a Chronogram button. In the release notes for Logisim-evolution the chronogram work was merged in a 3.4.4 pre-release and described as working again in 3.5.0 (release history). In 5.0.0 it is a menu item, Simulate, then Timing diagram. The 5.0.0 strings still contain an older message, “Add ‘sysclk’ signal in Simulate->Chronogram…”, which we did not see in the window.

Timing diagrams in classic 2.7.1

Classic has no timing diagram. Simulate, then Logging, opens a window with three tabs, Selection, Table and File (F98). Selection lists the components and has Add, Change Radix, Move Up, Move Down and Remove buttons.

LAB lab-lnx · Linux lab2.7.12026-11-11

The Logging window of classic Logisim 2.7.1 on its Selection tab. The left list shows Clock, Counter, halt and Q. Buttons: Add, Change Radix, Move Up, Move Down, Remove and Close Window.

Classic 2.7.1, Simulate, Logging, Selection tab, Linux lab (F98).lab-lnx-l271-logging-selection-01
Selection tab of the classic 2.7.1 Logging window listing Clock, Counter, halt and Q.

The File tab reads “File output disabled.” with an Enable button, a file box, a Select button and a ticked Include Header Line box.

LAB lab-lnx · Linux lab2.7.12026-11-11

The File tab of the classic 2.7.1 Logging window. It reads File output disabled, with a greyed-out Enable button, an empty File box, a Select button and a ticked Include Header Line box.

Classic 2.7.1 Logging window, File tab, Linux lab (F98).lab-lnx-l271-logging-file-01
File tab of the classic 2.7.1 Logging window: File output disabled, empty File box, Select button.

We did not write a log file, so we cannot describe its contents. For a waveform from classic, log to a file and draw it with an external tool, or use Logisim-evolution. See Classic Logisim 2.7.1 today.

Frequently asked questions

How do I get a timing diagram in Logisim?

In Logisim-evolution choose Simulate, then Timing diagram. Pick Clocked mode and a clock on the Options tab, then step the clock with Ctrl+T or run it with Ctrl+K. The waveform appears on the Timing diagram tab (F97).

Why is the timing diagram empty?

Usually no signals are chosen, the clock has not ticked, or the mode needs a clock that the circuit does not have. The window says so with a message. Click Add or Remove on the Options tab, then tick the clock once with Ctrl+T in the main window.

How do I export the timing diagram as an image?

In the timing window choose File, then Export Image. The file types we saw were PNG, GIF, JPEG, TikZpicture, SVG and WaveDrom, and each wrote a file (F97).

Does Logisim 2.7.1 have a timing diagram?

No. Classic has Simulate, then Logging, with Selection, Table and File tabs, but no waveform (F98).

Can I log signal values to a file?

In classic 2.7.1 yes: the Logging window has a File tab (F98). We did not find a file option in the 5.0.0 timing diagram window, but you can export its data as WaveDrom text.

Sources

  1. Logisim-evolution releases and change notes, GitHub, accessed 9 Nov 2026
  2. Timing diagram window strings in 5.0.0, logisim.dev lab data: test-data/lab5-2026-11-11-components2/strings-le500-en-all.tsv
  3. What we saw in the windows, logisim.dev lab data: test-data/FINDINGS.md F97, F98; test-data/lab14-2026-11-11-timing/

Try: , , ,