Logisim cannot modify circuit and every other Logisim error message

Search for the words of your message below, or pick its group: starting Logisim, opening and saving files, simulation, editing, memory images, command line, test vectors, Combinational Analysis or FPGA. Each entry quotes the exact text, says where it appears and in which versions, and gives the fix, most likely first. The most common one, Cannot modify circuit. (searched for as Logisim cannot modify circuit), means you are trying to edit a circuit that belongs to a loaded library, not to your own file.
FOR
Logisim-evolution 5.0.0 and classic 2.7.1
CHECKED
11 Nov 2026
Checked against Logisim-evolution 5.0.0 on 4 machines
On this page

Most searched

Starting Logisim

Java, macOS, Windows and package-manager messages seen before the main window opens.

#Error: A JNI error has occurred, please check your installation and try again

Tested by usF20 F275.0.0
Error: A JNI error has occurred, please check your installation and try again

Terminal, or a Java error dialog. The 5.0.0 jar started with Java 8.

java.lang.UnsupportedClassVersionError: com/cburch/logisim/Main has been compiled by a more recent version of the Java Runtime (class file version 65.0), this version of the Java Runtime only recognizes class file versions up to 52.0

What it means

The 5.0.0 jar was built for Java 21 and your Java is older. The number in the message is the class file version: 52 is Java 8, 55 is Java 11, 61 is Java 17, 65 is Java 21.

Class file version and the Java it needs
Class file versionJava
528
5511
6117
6521 (needed by 5.0.0)

Fixes, most likely first

  1. Use the installer for your system (MSI, DMG, DEB or RPM). It bundles its own Java, so the system Java does not matter. tested by us
  2. Or install Java 21 and start the jar with java -jar Logisim-evolution-5.0.0-all.jar. Check with java -version first. tested by us

RelatedJava requirements and Java errorsLogisim won't open: launch troubleshootingDownload Logisim safely (all official builds)

#Error: LinkageError occurred while loading main class com.cburch.logisim.Main

Tested by usF205.0.0
Error: LinkageError occurred while loading main class com.cburch.logisim.Main

Terminal. The 5.0.0 jar started with Java 17.

java.lang.UnsupportedClassVersionError: com/cburch/logisim/Main has been compiled by a more recent version of the Java Runtime (class file version 65.0), this version of the Java Runtime only recognizes class file versions up to 61.0

What it means

The same cause as the entry above, reported by Java 17 in a different wording: the jar needs Java 21.

Fixes, most likely first

  1. Install Java 21, or use the installer, which bundles it. tested by us

RelatedError: A JNI error has occurred, please check your installation and try againJava requirements and Java errors

#java.awt.AWTError: Assistive Technology not found: org.GNOME.Accessibility.AtkWrapper

Tested by usF212.7.1
java.awt.AWTError: Assistive Technology not found: org.GNOME.Accessibility.AtkWrapper

Terminal. Classic 2.7.1 on Ubuntu with openjdk-8-jre-headless.

What it means

Java tried to load a GNOME accessibility bridge that this runtime does not include, and stopped before opening a window.

Fixes, most likely first

  1. Run 2.7.1 with Java 17 or 21. It starts on both (F21). tested by us
  2. Or start it with -Djavax.accessibility.assistive_technologies=" " in front of -jar. not tested by us

A related packaged-runtime case was fixed upstream in 5.0.0 (issue 2398). We did not test that fix.

RelatedClassic Logisim 2.7.1 todayJava requirements and Java errors

#Exception in thread "main" java.awt.HeadlessException

Tested by usF185.0.0
Exception in thread "main" java.awt.HeadlessException

Terminal. 5.0.0 with --test-vector or --new-file-format and no display; exit code 1.

What it means

These two options open windows, so they cannot run without a screen. The --tty mode does run headless.

Fixes, most likely first

  1. On a server or in CI, start a virtual display first (Xvfb) and run the same command. tested by us
  2. If you only need a truth table or a halt run, use --tty instead. tested by us

RelatedCommand line (tty) referenceTest Vector Builder and Checker

#Error: Invalid or corrupt jarfile …

Users reportF245.0.02.7.1
Error: Invalid or corrupt jarfile …

Terminal. Any jar.

What it means

Java could not read the file as a jar. The usual reason is an incomplete download, or a web page saved under a .jar name.

Fixes, most likely first

  1. Download again from the release page and compare the size and SHA-256 with the table on the download page (the 5.0.0 jar is 54,448,596 bytes). not tested by us

We have not reproduced this message with a truncated jar yet.

RelatedDownload Logisim safely (all official builds)

#macOS: “Logisim-evolution” Not Opened

Tested by usF64 F295.0.0
“Logisim-evolution” Not Opened

macOS 15 dialog on first launch of the app from the DMG, with buttons Done and Move to Trash. Captured on macOS 15.8.2 (Apple Silicon).

Apple could not verify “Logisim-evolution” is free of malware that may harm your Mac or compromise your privacy.
LAB ci-mac-arm · GitHub-hosted macOS 155.0.02026-11-09

A macOS dialog with a yellow warning triangle titled "Logisim-evolution" Not Opened. The text says Apple could not verify it is free of malware that may harm your Mac or compromise your privacy. The only buttons are Done and Move to Trash.

The first start of the Apple Silicon app on macOS 15: the dialog offers only Done and Move to Trash, with no Open button (F29, F64).ci-mac-arm-le500-gatekeeper-not-opened-01
macOS dialog: Logisim-evolution Not Opened, Apple could not verify it; buttons Done and Move to Trash.

What it means

The app is ad-hoc signed and not notarized by Apple, so Gatekeeper blocks a file that carries the quarantine flag from a browser download. It is not a malware finding. The dialog has no Open button.

Fixes, most likely first

  1. Click Done, not Move to Trash. from Apple or Microsoft documentation, not tested by us
  2. Open System Settings, Privacy and Security, scroll to the message about Logisim-evolution and choose Open Anyway, then confirm with your password. from Apple or Microsoft documentation, not tested by us
  3. Or remove the flag in Terminal: xattr -dr com.apple.quarantine /Applications/Logisim-evolution.app (we confirmed the flag is removed, F29). tested by us

Both override paths follow Apple documentation and were not clicked through by us.

RelatedInstall Logisim on macOS (Apple Silicon and Intel)Logisim won't open: launch troubleshooting

#"Logisim-evolution" is damaged and can't be opened. You should move it to the Trash.

Users reportF295.0.0
"Logisim-evolution" is damaged and can't be opened. You should move it to the Trash.

macOS dialog after downloading the DMG on older macOS versions (community reports). Not seen on our macOS 15 runner, which shows the Not Opened dialog.

What it means

Same cause as the Not Opened dialog: the quarantine flag on an app that Apple has not notarized.

Fixes, most likely first

  1. Follow the fixes in the entry for the Not Opened dialog, in particular the xattr command. not tested by us

RelatedmacOS: “Logisim-evolution” Not OpenedInstall Logisim on macOS (Apple Silicon and Intel)Logisim won't open: launch troubleshooting

#“Logisim-evolution” cannot be opened because Apple cannot check it for malicious software.

Users reportF29 F645.0.0
“Logisim-evolution” cannot be opened because Apple cannot check it for malicious software.

macOS first launch on older versions (community reports).

“Logisim-evolution” cannot be opened because the developer cannot be verified.

What it means

The older wording of the same Gatekeeper block. On macOS 15 the dialog reads as the Not Opened entry above.

Fixes, most likely first

  1. Control-click the app and choose Open (older macOS), or use the Privacy and Security route and the xattr command from the Not Opened entry. from Apple or Microsoft documentation, not tested by us

RelatedmacOS: “Logisim-evolution” Not OpenedInstall Logisim on macOS (Apple Silicon and Intel)

#To open "Logisim" you need to install the legacy Java SE 6 runtime.

Users report2.7.1
To open "Logisim" you need to install the legacy Java SE 6 runtime.

macOS, classic 2.7.1 .app bundle.

What it means

The old app bundle asks for Apple's Java 6 runtime, which current macOS does not ship.

Fixes, most likely first

  1. Do not install Java 6. Run the 2.7.1 jar with Java 21 instead: java -jar logisim-generic-2.7.1.jar. not tested by us

Seen in community reports; we have not reproduced it.

RelatedClassic Logisim 2.7.1 todayInstall Logisim on macOS (Apple Silicon and Intel)

#Windows protected your PC

Tested by usF255.0.0
Windows protected your PC

Windows SmartScreen when you run the downloaded MSI.

What it means

The MSI is not digitally signed (F25), so SmartScreen warns about an unrecognised publisher. The warning alone is not evidence of a problem.

Fixes, most likely first

  1. If the file came from the release page and its SHA-256 matches the download page, choose More info, then Run anyway. from Apple or Microsoft documentation, not tested by us

The exact button wording is cited, not captured by us.

RelatedInstall Logisim on WindowsDownload Logisim safely (all official builds)

#This app can't run on your PC

Users report5.0.0
This app can't run on your PC

Windows.

What it means

Windows says this for a file built for another processor type, or for a damaged download.

Fixes, most likely first

  1. Download the MSI that matches your processor (amd64 for most PCs, aarch64 for Windows on Arm). not tested by us

RelatedInstall Logisim on WindowsDownload Logisim safely (all official builds)

#Error: Cask 'logisim-evolution' has been disabled because it does not pass the macOS Gatekeeper check! It w…

Tested by usF315.0.0
Error: Cask 'logisim-evolution' has been disabled because it does not pass the macOS Gatekeeper check! It was disabled on 2026-09-01.

Terminal: brew install --cask logisim-evolution. (Our CI runner prefixed the line with ::error::; that prefix is not part of the text.)

What it means

Homebrew disabled the cask because the app is not notarized. The cask was also stuck at version 4.1.0.

Fixes, most likely first

  1. Use the DMG from the release page and follow the macOS install guide. tested by us

RelatedInstall Logisim on macOS (Apple Silicon and Intel)

#…/gtk-query-immodules-3.0: symbol lookup error: …/libgtk-3.so.0: undefined symbol: pango_font_family_get_face

Tested by usF533.8.0
…/gtk-query-immodules-3.0: symbol lookup error: …/libgtk-3.so.0: undefined symbol: pango_font_family_get_face

Terminal. Snap logisim-evolution (3.8.0, revision 4) on Ubuntu 24.04.

What it means

The Snap bundles its own GTK and prints this on start. The app still runs, and --tty gave a correct table. The bigger issue is that the Snap is 3.8.0 from March 2023.

Fixes, most likely first

  1. Use the .deb or the Flatpak instead, which install 5.0.0. tested by us

RelatedInstall Logisim on Linux

#PKGBUILD: line 34: unzip: command not found

Tested by usF55 F60 F205.0.0
PKGBUILD: line 34: unzip: command not found

Terminal: makepkg for the AUR package logisim-evolution-bin on a clean Arch system.

What it means

The PKGBUILD uses unzip without declaring it. It also declares java-runtime>=16 although 5.0.0 needs Java 21.

Fixes, most likely first

  1. Install unzip (sudo pacman -S unzip) and run makepkg again. The package then builds, installs and runs (F60). tested by us
  2. Check that the Java it picks is 21 or newer. tested by us

RelatedInstall Logisim on Linux

#xdg-mime: No writable system mimetype directory found.

Tested by usF545.0.0
xdg-mime: No writable system mimetype directory found.

Terminal: dnf remove logisim-evolution with the release RPM in a minimal Fedora container.

%preun(logisim-evolution-5.0.0-1.x86_64) scriptlet failed, exit status 3

What it means

The package's uninstall script could not update the MIME database. We saw it only in a minimal container where that directory does not exist. It should not appear on a normal Fedora desktop, but we have not confirmed that on a full install.

Fixes, most likely first

  1. Nothing to fix for a container. On a desktop, report it with your Fedora version if it appears. not tested by us

Seen in a container only.

RelatedInstall Logisim on Linux

#WARNING: Note: Java needs to be installed before using Logisim Evolution.

Tested by usF57 F205.0.0
WARNING: Note: Java needs to be installed before using Logisim Evolution.

Terminal: choco install logisim-evolution (5.0.0).

What it means

Chocolatey installs the all-in-one jar, not the MSI, so it needs Java 21. Scoop's extras bucket does the same and suggests java/openjdk.

Fixes, most likely first

  1. Install Java 21 first, or use winget or the MSI, which bundle Java. tested by us

RelatedInstall Logisim on WindowsJava requirements and Java errors

#Windows Defender Firewall has blocked some features of this app

Users report5.0.0
Windows Defender Firewall has blocked some features of this app

Windows, first launch. Wording assumed from the standard Windows prompt; not captured by us.

What it means

Users report a firewall prompt on first launch, which they trace to the update check. We did not capture it on 5.0.0.

Fixes, most likely first

  1. Allowing or denying network access does not stop the editor from working; the update check is the only network use we know of. not tested by us

Unconfirmed on 5.0.0.

RelatedInstall Logisim on Windows

Opening and saving files

Dialogs from loading, merging and saving a .circ file.

#Old file format -- compatibility mode

Tested by usF02 F03 F04 F45 F495.0.0
You are opening a file created with original Logisim code. You might encounter some problems in the execution, since some components evolved since then. Moreover, labels will be converted to match VHDL limitations for variable names.

Dialog titled “Old file format -- compatibility mode” in 5.0.0 when the file was saved by a version before 2.7.2. The same text goes to the log in tty mode.

LAB lab-lnx · Linux lab5.0.02026-11-09

A dialog titled "Old file format -- compatibility mode" with a warning icon. It says: You are opening a file created with original Logisim code. You might encounter some problems in the execution, since some components evolved since then. Moreover, labels will be converted to match VHDL limitations for variable names. There is one OK button.

What 5.0.0 shows when you open a classic-format file. It is a warning: click OK (F02).lab-lnx-le500-compat-mode-dialog-01
Dialog Old file format, compatibility mode: you are opening a file created with original Logisim code.

What it means

A warning, not an error. 5.0.0 is converting a classic-format file and will rename labels that break VHDL naming.

Fixes, most likely first

  1. Click OK. tested by us
  2. If wires stay grey and pins show 0, click an empty spot on the canvas or press Ctrl+R (Simulate, Reset Simulation). This happens after opening any file, including one saved by 5.0.0 (F45, F49). tested by us
  3. Keep a copy before you save. Once saved by 5.0.0 the file no longer opens in 2.7.1 (F04). tested by us

RelatedThe .circ file: open, convert, compatibility.circ Viewer and InspectorWire colours and values (E, X, U, orange)

#The built-in library FPArithmetic is not available in this version.

Tested by usF042.7.15.0.0
The built-in library FPArithmetic is not available in this version.

Classic 2.7.1 dialog titled File Error when opening a file saved by 5.0.0 (first line). The second line is the 5.0.0 variant of the template, with curly quotes.

The built-in library “…” is not available in this version.
LAB lab-lnx · Linux lab2.7.12026-11-09

A classic Logisim 2.7.1 dialog titled File Error with a red stop icon. The text starts: full-adder-v5: The built-in library FPArithmetic is not available, and continues past the edge of the box. There is one OK button.

Classic 2.7.1 refuses a file saved by 5.0.0, even a plain full adder, because every 5.0.0 file declares the Floating Point Arithmetic library (F04).lab-lnx-l271-file-error-fparithmetic-01
Classic 2.7.1 File Error dialog: the built-in library FPArithmetic is not available.

What it means

The file uses a library that exists only in newer Logisim, and 2.7.1 does not have it.

Fixes, most likely first

  1. Open the file in Logisim-evolution (see the download page). tested by us
  2. Or ask whoever wrote it for a copy that avoids newer components. There is no safe automatic conversion back to the 2.7.1 format. tested by us

Users also report variants that name other libraries, such as HDL-IP and TCL.

RelatedDownload Logisim safely (all official builds)The .circ file: open, convert, compatibility

#Error encountered opening …: …

Message text from the 5.0.0 source5.0.02.7.1
Error encountered opening …: …

Both versions.

What it means

A wrapper. The part after the colon is the real reason, and is usually one of the other entries in this group.

Fixes, most likely first

  1. Read the second half of the message and look it up here. not tested by us

RelatedThe .circ file: open, convert, compatibility

#XML formatting error: …

Message text from the 5.0.0 source5.0.02.7.1
XML formatting error: …

Both versions.

What it means

The file is not valid XML. A .circ file is XML, so this means it is damaged or is not a Logisim file at all.

Fixes, most likely first

  1. Open the file in a text editor. If it starts with an HTML tag, you saved a web page instead of the file (for example, Save link as on a GitHub file view). Download the raw file instead. not tested by us
  2. Check the file in the .circ viewer. not tested by us

Related.circ Viewer and InspectorThe .circ file: open, convert, compatibility

#The required library file ‘…’ is missing. Please select the file from the following dialog.

Message text from the 5.0.0 source5.0.0
The required library file ‘…’ is missing. Please select the file from the following dialog.

Dialog titled Locate ‘…’ in 5.0.0.

What it means

The project loads another .circ or .jar as a library, and that file is not where the project expects it.

Fixes, most likely first

  1. Select the file in the dialog that follows, and keep the project and its libraries in one folder. not tested by us

RelatedLibraries, merging and copying circuits

#Component not found or missing from library

Message text from the 5.0.0 source5.0.0
component ‘…’ not found

On load, 5.0.0.

component ‘…’ missing from library ‘…’

What it means

The file uses a component this version does not have.

Fixes, most likely first

  1. Open the file in the version that saved it. The .circ viewer lists the version recorded in the file. not tested by us

Related.circ Viewer and InspectorThe .circ file: open, convert, compatibility

#Cannot save file

Message text from the 5.0.0 sourceF525.0.0
Could not save file: …

Dialogs titled Cannot save file and File Not Available, 5.0.0.

You do not have permission to write to “….”

What it means

Logisim could not write to the place you chose.

Fixes, most likely first

  1. Save to a different folder, such as one inside your home folder. not tested by us
  2. On macOS, a jar started by double-click may lack permission for Desktop or Documents. Run it from Terminal, or use the installer app. not tested by us
  3. In the Flatpak, files outside your home folder are not visible at all; save inside your home folder (F52). tested by us

RelatedInstall Logisim on LinuxInstall Logisim on macOS (Apple Silicon and Intel)

#Failed to create autosave for file: ‘…’. Will not try again for this file until after a restart.

Message text from the 5.0.0 source5.0.0
Failed to create autosave for file: ‘…’. Will not try again for this file until after a restart.

5.0.0 (autosave exists since 3.9.0).

What it means

The folder next to your file is not writable, so Logisim gave up on autosave for this file.

Fixes, most likely first

  1. Save manually now, and move the file to a writable folder. not tested by us

RelatedLogisim FAQ

#Components … and … exactly overlap each other. One has been moved slightly.

Message text from the 5.0.0 source5.0.0
Components … and … exactly overlap each other. One has been moved slightly.

On load, 5.0.0.

What it means

Two identical components sit at the same spot, for example in a hand-edited or merged file. Logisim moved one.

Fixes, most likely first

  1. Check that the moved component is wired as you expect. not tested by us

RelatedThe .circ file: open, convert, compatibility

#Circular reference

Message text from the 5.0.0 source5.0.02.7.1

The two tool messages appear in both versions; the two file messages in 5.0.0.

  • The file … contains within it a reference to itself.
  • Cannot create circular reference. (The file is used by the … library.)
  • Cannot add a subcircuit that uses this circuit, as it creates a circular reference.
  • Cannot paste a subcircuit that uses this circuit, as it creates a circular reference.

What it means

A circuit cannot contain itself, directly or through other circuits or libraries.

Fixes, most likely first

  1. Break the loop: replace the inner use with a copy, or move the shared part into a third circuit that both use. not tested by us

RelatedSubcircuits and custom appearance

#Circuit ‘…’ cannot be merged as the original project already contains a tool/circuit with the same name in …

Message text from the 5.0.0 source5.0.0
Circuit ‘…’ cannot be merged as the original project already contains a tool/circuit with the same name in loaded library ‘…’

Dialog titled Circuit name conflict, 5.0.0 merge or import.

What it means

The project you merge into already has a circuit or tool with that name.

Fixes, most likely first

  1. Rename one of the two circuits and merge again. not tested by us

RelatedLibraries, merging and copying circuits

#Could not open file: …

Message text from the 5.0.0 source5.0.0
Could not open file: …

Dialog titled Error During Open, 5.0.0.

What it means

The file is missing, moved or not readable.

Fixes, most likely first

  1. Check the path and the permissions, and try another folder. not tested by us

RelatedThe .circ file: open, convert, compatibility

Simulation

Status-line messages and wire values while a circuit runs.

#Oscillation apparent

Tested by usF065.0.02.7.1
Oscillation apparent

Status line at the bottom of the canvas, both versions. Command line: halted due to detected oscillation. Test vector: oscillating.

LAB lab-lnx · Linux lab5.0.02026-11-09

Logisim-evolution 5.0.0 canvas with a NOT gate whose output wire loops back to its own input. The wire is red, and the output pin Q shows E.

A NOT gate fed by its own output. The loop is drawn red and the pin reads E (F06).lab-lnx-le500-oscillation-loop-01
A NOT gate whose output wire loops back to its own input: the wire is red and the output pin shows E.

What it means

A feedback loop never settles. In tty output a NOT gate wired to itself shows E and no text (F06).

Fixes, most likely first

  1. Break the loop, or add a flip-flop or latch that really stores a value. The full guide has the cases and the fix for each. tested by us

RelatedFix "Oscillation apparent"

#Incompatible widths

Tested by usF095.0.02.7.1
Incompatible widths

Status line at the bottom of the canvas, with an orange wire; both versions.

LAB lab-lnx · Linux lab5.0.02026-11-09

Logisim-evolution 5.0.0 window with four test wires. Three of them are grey and their pins show 0. The fourth, from a 4-bit input to a 1-bit pin, is orange, with the words Incompatible widths at the bottom of the canvas.

Right after opening the file, the wires are grey and pins show 0 because the simulation has not run yet. Only the orange width error is already drawn.lab-lnx-le500-wire-colours-grey-before-reset-01
Four test wires: three grey with pins at 0, and an orange one with Incompatible widths at the bottom.

What it means

Two things with different bit widths meet on one wire, for example a 4-bit bus into a 1-bit pin. The output reads U for every input (F09).

Fixes, most likely first

  1. Click the orange wire and the pins at its ends and make the Data Bits match, or split the bus with a splitter. tested by us

RelatedWire colours and values (E, X, U, orange)Splitter

#Simulation halted by internal error

Message text from the 5.0.0 source5.0.02.7.1
Simulation halted by internal error

Canvas, both versions.

What it means

A bug in a component or in the simulator.

Fixes, most likely first

  1. Save under a new name, choose Simulate, Reset Simulation, and reopen the file. If it repeats, report it upstream with the file. not tested by us

RelatedContact

#Value E (red wire)

Tested by usF075.0.02.7.1
E

A red wire, or the value E on a probe or in tty output.

What it means

Two outputs drive the same wire with different values. Equal values give that value (F07).

Fixes, most likely first

  1. Find the second driver and remove it, or put a tri-state or a multiplexer in front of one. tested by us

RelatedWire colours and values (E, X, U, orange)

#Value U (blue wire)

Tested by usF085.0.02.7.1
U

A blue wire, or the value U on a pin or in tty output. Older documents write X.

What it means

Nothing drives the wire (F08). 5.0.0 shows U where older text says X.

Fixes, most likely first

  1. Connect an output or constant to the wire. Also check the previous entry about widths, which shows U on the output. tested by us

RelatedWire colours and values (E, X, U, orange)

Editing circuits

Refusals while you place, move, name or delete things.

#Cannot modify circuit.

Message text from the 5.0.0 source5.0.02.7.1
Cannot modify circuit.

The first is the canvas status line; the second appears when you change an attribute. Identical strings in the 2.7.1 jar and the 5.0.0 source.

This circuit cannot be modified.

What it means

The circuit on screen is not part of the file you have open. It belongs to a library loaded with Project, Load Library, Logisim Library, and library circuits are read-only. In the 5.0.0 source the Add, Wiring, Select and Text tools refuse when the project file does not contain the shown circuit.

Fixes, most likely first

  1. Open the library's own .circ file and edit it there, then reload the library. not tested by us
  2. Copy the circuit into your own project (5.0.0 can merge or export circuits). not tested by us
  3. Check the circuit list on the left: you may have double-clicked into a library subcircuit instead of your own. not tested by us

Cause confirmed from the source; not yet reproduced and photographed by us.

RelatedLibraries, merging and copying circuitsSubcircuits and custom appearance

#Conflicting component already there.

Message text from the 5.0.0 source5.0.02.7.1
Conflicting component already there.

Both versions.

What it means

You tried to place a component where an exclusive one already is.

Fixes, most likely first

  1. Move one of them. not tested by us

RelatedSubcircuits and custom appearance

#Component cannot have negative coordinates.

Message text from the 5.0.0 source5.0.0
Component cannot have negative coordinates.

5.0.0.

What it means

The component would end up past the top or left edge.

Fixes, most likely first

  1. Move it right or down, or select everything and shift it first. not tested by us

#Attribute unchanged because request is invalid

Message text from the 5.0.0 source5.0.0
Attribute unchanged because request is invalid

Dialog titled Value Invalid, 5.0.0.

What it means

The value you typed is not allowed for that attribute.

Fixes, most likely first

  1. Use a value from the list or the range the attribute accepts. not tested by us

RelatedPins, probes and constants

#The name is invalid (it must follow the rule ([a-zA-Z]+\w*)).

Message text from the 5.0.0 sourceF02 F705.0.0

Dialogs in 5.0.0 when naming circuits and labelling components. The rules are stricter than in 2.7.1 because names must be valid VHDL.

  • The name is invalid (it must follow the rule ([a-zA-Z]+\w*)).
  • This name is a keyword and can therefore not be used.
  • This name is already in use in your project and can therefore not be used.
  • Every circuit requires a name.
  • Label is a reserved keyword and cannot be used. Please specify a different label.
  • Label and component name may not be the same (they are case-insensitive). Please specify a label different from the component name.
  • There exists already a component with this label! Please use unique labels in a circuit.
  • The specified label equals a VHDL keyword. Please specify another name.
  • The specified label equals a Verilog keyword. Please specify another name.
  • Library must contain at least one circuit.
LAB lab-lnx · Linux lab5.0.02026-11-11

Logisim-evolution 5.0.0 message dialog that reads: alu1 : One component in the circuit has the same label as the component name of the newly placed component. This label has been removed! It has an info icon and one OK button.

The dialog Logisim shows when a file holds a component labelled with the same name as a circuit or component. In test-vector mode it waits for OK, so a scripted run hangs.lab-lnx-le500-label-conflict-dialog-01
Message dialog: a component in the circuit has the same label as the newly placed component, so the label was removed.

What it means

Names and labels follow VHDL and Verilog rules so the circuit can be exported.

Fixes, most likely first

  1. Start with a letter, then use letters, digits and underscores only. not tested by us
  2. Avoid keywords such as AND, NAND or NOT, and do not give a component a label equal to its own name. not tested by us
  3. Keep labels unique inside one circuit. not tested by us

The label-equals-name case is the one our lab hit (F70).

RelatedSubcircuits and custom appearancePins, probes and constants

Memory images (ROM and RAM)

Loading hex images in the GUI and with –load.

#Hex file header not recognized

Tested by usF155.0.0
Hex file header not recognized

5.0.0, Load Image in the GUI and --load on the command line.

What it means

The first line of the image is not a known format header. A plain list such as 0x11 0x22 is rejected and the memory stays empty.

Fixes, most likely first

  1. Make the first line exactly v2.0 raw, then the words in hexadecimal without 0x. tested by us

RelatedMemory Image Generator (ROM/RAM files)

#Decoding with format 'v2.0 raw' produced 1 warnings.

Tested by usF155.0.0
Decoding with format 'v2.0 raw' produced 1 warnings.

5.0.0.

Line 2: "zz" is not valid hex data.

What it means

One token is not hexadecimal. That word loads as 0 and the rest load normally.

Fixes, most likely first

  1. Fix the token on the line named. tested by us

RelatedMemory Image Generator (ROM/RAM files)

#No message: a value that is too wide is cut off

Tested by usF155.0.0
(no message)

5.0.0.

What it means

A value wider than the memory's Data Bit Width is cut off with no warning: 100 in an 8-bit ROM becomes 00.

Fixes, most likely first

  1. Check widths with the memory image checker before you load. tested by us

RelatedMemory Image Generator (ROM/RAM files)

#Image file has invalid format header

Message text from the 2.7.1 jar2.7.1
Image file has invalid format header.

Classic 2.7.1 dialog titled Load Error.

Image file has some invalid contents.
Image file has too much information.

What it means

Classic 2.7.1 accepts only the v2.0 raw header.

Fixes, most likely first

  1. Use v2.0 raw as the first line. not tested by us

RelatedMemory Image Generator (ROM/RAM files)

#Memory Image Load Error

Message text from the 5.0.0 source5.0.02.7.1
Memory Image Load Error

Dialog title in 5.0.0 (2.7.1 uses Load Error).

What it means

A wrapper title. The body names the actual problem and matches another entry in this group.

Fixes, most likely first

  1. Read the body of the dialog. not tested by us

RelatedMemory Image Generator (ROM/RAM files)

#The clipboard contents cannot be pasted into the editor.

Message text from the 5.0.0 source5.0.0
The clipboard contents cannot be pasted into the editor.

Hex editor (Edit Contents).

What it means

The pasted text is not hex words in the layout the editor expects.

Fixes, most likely first

  1. Paste plain hex words, or write a file and use Load Image. not tested by us

RelatedMemory Image Generator (ROM/RAM files)

Command line

Messages from –tty, –load, –save and the other options.

#Invalid arguments for “--load”. Auguments should be <file> [label].

Tested by usF165.0.0
Invalid arguments for “--load”. Auguments should be <file> [label].

5.0.0. The typo “Auguments” is in Logisim's own text.

What it means

--load takes every following argument as its own, so the .circ file has to come first.

Fixes, most likely first

  1. Put the circuit before the option: --tty table circuit.circ --load image.txt [label]. tested by us

RelatedCommand line (tty) referenceMemory Image Generator (ROM/RAM files)

#The “--load” option works only in conjunction with “--tty”.

Message text from the 5.0.0 source5.0.02.7.1
The “--load” option works only in conjunction with “--tty”.

First line 5.0.0, second line 2.7.1.

The "-load" option works only in conjunction with "-tty".

What it means

Memory images load only in tty mode.

Fixes, most likely first

  1. Add a --tty format. not tested by us

RelatedCommand line (tty) reference

#No RAM/ROM was found for the “--load” labels: …

Message text from the 5.0.0 source5.0.0
No RAM/ROM was found for the “--load” labels: …

5.0.0.

What it means

The label after the file does not match any ROM or RAM.

Fixes, most likely first

  1. Check the label in the component's attribute table. not tested by us

RelatedCommand line (tty) referenceMemory Image Generator (ROM/RAM files)

#“--tty” requires at least one of the following: halt, speed, stats, table, tty, binary, hex, csv, tabs

Message text from the 5.0.0 sourceF015.0.0
“--tty” requires at least one of the following: halt, speed, stats, table, tty, binary, hex, csv, tabs

5.0.0.

What it means

You gave --tty without a valid format.

Fixes, most likely first

  1. Add one of the formats named in the message. not tested by us

RelatedCommand line (tty) reference

#Using “--tty” requires a filename provided on command line.

Message text from the 5.0.0 source5.0.0
Using “--tty” requires a filename provided on command line.

5.0.0.

What it means

There is no .circ path on the command line.

Fixes, most likely first

  1. Add the path to the circuit. not tested by us

RelatedCommand line (tty) reference

#Error loading circuit file: …

Message text from the 5.0.0 source5.0.02.7.1
Error loading circuit file: …

Both versions.

What it means

The path is wrong or the file cannot be read.

Fixes, most likely first

  1. Check the path and permissions. not tested by us

RelatedCommand line (tty) reference

#No TTY or Keyboard component was found.

Message text from the 5.0.0 source5.0.0
No TTY or Keyboard component was found.

5.0.0.

What it means

--tty tty needs a TTY or Keyboard component in the circuit.

Fixes, most likely first

  1. Add one, or choose another format. not tested by us

RelatedCommand line (tty) reference

#The “--save” option works only in conjunction with “--tty”.

Message text from the 5.0.0 source5.0.0
The “--save” option works only in conjunction with “--tty”.

5.0.0.

No RAM was found for the “--save” option.

What it means

As the messages say.

Fixes, most likely first

  1. Add --tty, and make sure the circuit contains a RAM. not tested by us

RelatedCommand line (tty) reference

#Argument for --gates option must be “ANSI” or “IEC”.

Message text from the 5.0.0 source5.0.0
Argument for --gates option must be “ANSI” or “IEC”.

5.0.0.

What it means

The value after --gates is not one of the two.

Fixes, most likely first

  1. Use ANSI or IEC. not tested by us

RelatedCommand line (tty) reference

#Specified locale is not supported.

Message text from the 5.0.0 source5.0.0
Specified locale is not supported.

5.0.0.

Supported locales:

What it means

The language code is not in the list that follows.

Fixes, most likely first

  1. Use one of the codes listed. Chinese is zh. not tested by us

RelatedCommand line (tty) reference

Test vectors

Format errors and failing rows.

#Test vector does not match circuit

Message text from the 5.0.0 source5.0.0

Dialog titled Error Loading Test Vector, 5.0.0.

  • Test vector in “…” does not match circuit. Details: ….
  • Column … has no matching pin
  • Column … has width … but pin has width …
  • Column … has width … but clock has width 1

What it means

A column heading does not match an input or output pin, or the width differs.

Fixes, most likely first

  1. Make the header names equal to the pin labels, with the same case and spacing, and match the widths. not tested by us

RelatedTest Vector Builder and CheckerTest vectors and automated testing

#Test vector could not be parsed

Message text from the 5.0.0 source5.0.0

5.0.0.

  • Test vector in “…” could not be parsed. Detail: ….
  • Test Vector header format error: bad width: …
  • Test Vector data format error: too many values
  • Test Vector data format error: not enough values
  • TestVector format error: empty file

What it means

A syntax error at the line the detail names.

Fixes, most likely first

  1. Check the format rules and run the file through the test vector checker. not tested by us

RelatedTest Vector Builder and CheckerTest vectors and automated testing

#Error on test vector 8:

Tested by usF175.0.0
Error on test vector 8:

Command line, 5.0.0.

S = 1 (expected 0)
Passed: 7, Failed: 1

What it means

Not a format problem: your circuit gave a different output for that row.

Fixes, most likely first

  1. Open the circuit, set the inputs from row 8 and compare the output with the expected value. tested by us

RelatedTest vectors and automated testingTest Vector Builder and Checker

#No message: exit code 0 on a failing test vector

Tested by usF175.0.0
(no message; exit code 0)

Command line, 5.0.0.

What it means

A failing vector still exits with code 0, on every system we tried (F17).

Fixes, most likely first

  1. In a grader, parse the text for Failed: 0 instead of trusting the exit code. tested by us

RelatedLogisim for teachers and coursesTest Vector Builder and Checker

#Cannot show results while auto-ticking. Please stop clock first.

Message text from the 5.0.0 source5.0.0
Cannot show results while auto-ticking. Please stop clock first.

Dialog titled Auto-ticking not compatible with request, 5.0.0.

What it means

The clock is running while you ask for test-vector results.

Fixes, most likely first

  1. Turn off Simulate, Auto-Tick Enabled. not tested by us

RelatedTest vectors and automated testing

#You do not have permission to read to “….”

Message text from the 5.0.0 source5.0.0
You do not have permission to read to “….”

5.0.0. “read to” is Logisim's wording.

What it means

The file is not readable by Logisim.

Fixes, most likely first

  1. Check the file permissions, and on macOS the privacy settings for the folder. not tested by us

RelatedTest vectors and automated testing

Combinational Analysis

The Analyze Circuit window and the expression box.

#Analysis cannot handle more than … inputs

Message text from the 5.0.0 source5.0.0
Analysis cannot handle more than … inputs.

Dialog titled Cannot Analyze, 5.0.0.

Analysis cannot handle more than … outputs.

What it means

The analyser has limits of 20 inputs and 256 outputs (AnalyzerModel).

Fixes, most likely first

  1. Split the circuit into parts and analyse each. not tested by us

RelatedCombinational Analysis: truth table to circuit

#Computing truth table instead of expression due to Tunnel.

Tested by usF485.0.0
Computing truth table instead of expression due to Tunnel.

Dialog titled Expression Not Determined, 5.0.0. The first line is the one we captured.

Circular reference detected; computing truth table instead.
Conflicting outputs detected; computing truth table instead.
LAB lab-lnx · Linux lab5.0.02026-11-09

Logisim-evolution 5.0.0 with a full adder built from gates and tunnels. A dialog titled Expression Not Determined says: Computing truth table instead of expression due to Tunnel. There is an OK button.

Analyze Circuit on a circuit that uses Tunnels. The notice is informational; the table still comes out right (F48).lab-lnx-le500-analysis-tunnel-warning-01
Dialog Expression Not Determined: Computing truth table instead of expression due to Tunnel.

What it means

The circuit uses a Tunnel, feedback or conflicting outputs, so Logisim computes the truth table by simulation. The window still shows the table, the sum-of-products expressions and the Karnaugh maps from it. In our full adder, S and Cout came out right (F48).

Fixes, most likely first

  1. For Tunnels the message is harmless: click OK. tested by us
  2. If you need expressions derived from the wiring, replace the Tunnels with wires. not tested by us

Only the Tunnel variant was reproduced. The other two lines are from the source.

RelatedCombinational Analysis: truth table to circuitTunnel

#Expression errors in the Analyze Circuit window

Message text from the 5.0.0 source5.0.0

The expression box in the Analyze Circuit window, 5.0.0.

  • Unrecognized characters: ‘…’
  • No matching closing parenthesis.
  • No matching opening parenthesis.
  • Operator “…” missing left operand.
  • Operator “…” missing right operand.
  • Unexpected apostrophe (“'”)
  • “…” is not an input variable.
  • Name must begin with a letter.
  • Name duplicates existing variable.

What it means

Syntax errors in a typed expression.

Fixes, most likely first

  1. Check the expression against the accepted syntax. not tested by us

RelatedTruth Table and K-Map to Logisim CircuitCombinational Analysis: truth table to circuit

#Logic function(s) is/are all don’t care or not optimized. Cannot build circuit. Please provide (a) valid fu…

Message text from the 5.0.0 source5.0.0
Logic function(s) is/are all don’t care or not optimized. Cannot build circuit. Please provide (a) valid function(s) or use the optimize button.

5.0.0, Build Circuit.

What it means

Every output is don't care, or the table has not been minimised.

Fixes, most likely first

  1. Set at least one 0 or 1, and press Minimize first. not tested by us

RelatedCombinational Analysis: truth table to circuitTruth Table and K-Map to Logisim Circuit

FPGA and HDL

Toolchain, mapping and HDL generation.

#Required tools not found in Directory “…” !

Message text from the 5.0.0 source5.0.0
Required tools not found in Directory “…” !

5.0.0, FPGA Commander.

What it means

The Vivado or Quartus path in Preferences is wrong.

Fixes, most likely first

  1. Point the preference at the folder that contains the tools. not tested by us

RelatedFPGA boards: synthesize and download

#Workspace directory may not contain spaces!

Message text from the 5.0.0 source5.0.0
Workspace directory may not contain spaces!

5.0.0.

What it means

The workspace path has a space.

Fixes, most likely first

  1. Choose a path without spaces. not tested by us

RelatedFPGA boards: synthesize and download

#Error found in stage “…”

Message text from the 5.0.0 source5.0.0
Error found in stage “…”

5.0.0.

What it means

A toolchain step failed.

Fixes, most likely first

  1. Read the console output of that tool. not tested by us

Not tested on a board by us.

RelatedFPGA boards: synthesize and download

#Intel FPGA cable "…" was not found. Detected cables: …

Message text from the 5.0.0 source5.0.0
Intel FPGA cable "…" was not found. Detected cables: …

5.0.0, --fpga-cable.

What it means

The cable name does not match one the tool detected.

Fixes, most likely first

  1. Use a name from the list the message prints. not tested by us

Not tested on a board by us.

RelatedFPGA boards: synthesize and download

#Not all IO components have been mapped to the board "BASYS3"; please map all components to continue!

Tested by usF515.0.0
Not all IO components have been mapped to the board "BASYS3"; please map all components to continue!

HDL generation, also --test-fpga … HDLONLY, which then exits with code 255. The board name varies.

What it means

HDL generation stops after the netlist and design-rule check because some pins have no board resource.

Fixes, most likely first

  1. Map every input and output to a board resource in the FPGA Commander, save the file, and run again. tested by us

RelatedFPGA boards: synthesize and downloadCommand line (tty) reference

#HDL generation: unsupported components, tri-state, widths, labels

Message text from the 5.0.0 source5.0.0

5.0.0, HDL generation.

  • Found one or more components in your circuit that are not supported for HDL generation.
  • Found a tri-state driver or floating output(s) for one or more components. This is not supported.
  • Found a bit width connection problem.
  • Found an invalid label.

What it means

The circuit contains something that cannot be turned into HDL.

Fixes, most likely first

  1. Replace the part, fix the width, or rename the label, then generate again. not tested by us

RelatedFPGA boards: synthesize and downloadVHDL and Verilog in Logisim-evolution

#VHDL simulation is not running. Enable it and check QuestaSim/ModelSim settings.

Message text from the 5.0.0 source5.0.0
VHDL simulation is not running. Enable it and check QuestaSim/ModelSim settings.

5.0.0.

What it means

VHDL entity simulation needs QuestaSim or ModelSim.

Fixes, most likely first

  1. Enable it in Preferences and set the tool path. not tested by us

RelatedVHDL and Verilog in Logisim-evolution

#There is no current hw_target

Users report5.0.0
There is no current hw_target

A Vivado message shown in the console.

What it means

Vivado cannot see a board.

Fixes, most likely first

  1. Check the cable driver, the USB connection and the board power. not tested by us

Not tested on a board by us.

RelatedFPGA boards: synthesize and download

Problems that show no message

Some failures show nothing at all. These are the ones we reproduced or that users report most.

Report a message we are missing

If your message is not here, send us the exact text, your Logisim version and your operating system through the contact page. If something on this page is wrong, tell us on the corrections page and we will fix it and note the change.

Frequently asked questions

What does 'Cannot modify circuit' mean in Logisim?

The circuit on screen is not part of the file you have open. It comes from a library loaded with Project, Load Library, Logisim Library, and library circuits are read-only. Open that library's own .circ file to edit it, or copy the circuit into your project. This cause comes from the program source; we have not yet photographed the message ourselves.

Why does Logisim say 'Old file format -- compatibility mode'?

You opened a file saved by a version before 2.7.2 in Logisim-evolution 5.0.0. It is a warning: click OK. Keep a copy before you save, because a file saved by 5.0.0 no longer opens in 2.7.1.

How do I fix UnsupportedClassVersionError when opening Logisim?

The 5.0.0 jar needs Java 21 and your Java is older. Use the installer for your system, which bundles Java, or install Java 21 and start the jar with java -jar.

Why does Logisim 2.7.1 say the built-in library FPArithmetic is not available?

The file was saved by Logisim-evolution, which has libraries 2.7.1 does not. Open the file in Logisim-evolution; there is no safe way to convert it back.

What does 'Hex file header not recognized' mean?

The first line of the memory image is not a known format header. Make it exactly v2.0 raw, then list the words in hexadecimal.

Sources

  1. Message text from the Logisim-evolution 5.0.0 English strings, logisim.dev lab data: test-data/lab5-2026-11-11-components2/strings-le500-en-messages.tsv
  2. Our reproductions of the messages marked Tested, logisim.dev lab data: test-data/FINDINGS.md (F02, F04, F06 to F09, F15 to F18, F20, F21, F25, F29, F31, F48, F51 to F57, F60, F64)

Try: , , ,